This manual provides essential guidance for the Superior Model 600 direct vent gas fireplace heater, ensuring safe installation, efficient operation, and proper maintenance for optimal performance and longevity.
The Superior Model 600 is a direct vent gas fireplace heater designed for efficient and reliable performance. Part of the 500/600/800 Series, it offers a combination of advanced technology and safety features. This appliance is engineered to provide consistent heat while maintaining energy efficiency. The Model 600 is suitable for various installation settings and comes with a comprehensive manual to guide users through its operation and maintenance. Its design ensures optimal airflow and combustion, making it a popular choice for homeowners seeking a durable and high-performing heating solution.
The manual is a critical resource for the Superior Model 600, providing detailed instructions for safe and proper installation, operation, and maintenance. It ensures compliance with safety standards and manufacturer guidelines, reducing the risk of accidents or performance issues. The manual includes troubleshooting tips, warranty information, and technical specifications, making it indispensable for both installers and users. Failure to follow the manual’s instructions may lead to unsafe conditions or void the warranty. Users are strongly encouraged to download and thoroughly review the manual to maximize the appliance’s efficiency and longevity.
The Superior Model 600 offers efficient heating, reliable performance, and advanced safety features, making it a top choice for homeowners seeking a durable and safe fireplace solution.
The Superior Model 600 features a sleek, modern design with a direct vent system, ensuring efficient heating and safety. Its sealed combustion chamber uses external air, minimizing heat loss and maximizing energy efficiency. The fireplace is designed for reliable performance, providing consistent warmth while maintaining low energy consumption.
The direct vent technology allows for flexible installation, accommodating both vertical and horizontal venting configurations. This design enhances safety by preventing carbon monoxide buildup and ensures optimal airflow for combustion. The Model 600 is engineered to deliver high heat output while maintaining eco-friendly operation, making it a practical choice for homeowners seeking both comfort and efficiency.
The Superior Model 600 is equipped with advanced safety features, including a sealed combustion chamber and 100% shut-off valves, ensuring safe operation. Its reliable design incorporates oxygen depletion sensors to monitor air quality and prevent hazardous conditions. The fireplace is built with durable, high-quality materials, enhancing longevity and performance. These features, combined with rigorous testing, make the Model 600 a trustworthy choice for homeowners seeking a safe and efficient heating solution.
Regular maintenance, as outlined in the manual, further ensures the fireplace operates reliably and safely, providing peace of mind for years of use.

Proper installation ensures safety and efficiency. A vent restrictor may be needed for vertical vent termination. Follow local codes and manufacturer guidelines for a secure setup.
Before installing the Superior Model 600, ensure compliance with local codes and regulations. Verify venting requirements, including the need for a vent restrictor in vertical setups. Check electrical compatibility and ensure the area is clear of flammable materials. Inspect existing systems for compatibility and proper sizing. Confirm all necessary tools and materials are available. Review the manual thoroughly to understand specific installation steps and safety precautions. Ensure proper ventilation and structural integrity to support the unit. Prepare the installation site according to manufacturer guidelines for a safe and efficient setup.
Proper venting is crucial for the Superior Model 600’s efficiency and safety. Use approved direct vent components, ensuring compatibility with the unit. A vent restrictor may be required for vertical terminations. Follow manufacturer guidelines for vent termination, including clearance from combustible materials and proper alignment. Ensure the vent system is sealed and securely installed to prevent leaks. Refer to local building codes for specific requirements. The venting system must be designed to handle the unit’s output and ensure safe exhaust of combustion byproducts. Consult the manual for detailed venting configurations and specifications to meet installation standards.
Ensure the Superior Model 600 is connected to a compatible electrical system. A licensed electrician should perform the installation to meet local codes. The unit requires a dedicated 120V power supply. Verify compatibility with your home’s electrical system before installation. Use the provided wiring diagram in the manual for accurate connections. Ensure all components, such as the control panel and ignition system, are properly grounded. The manual provides detailed instructions for electrical setup and troubleshooting common issues. Always follow safety guidelines to avoid electrical hazards and ensure reliable operation of the fireplace heater.

Learn to safely start and adjust the fireplace heater using the control panel. Follow guidelines for optimal performance and ensure all safety precautions are observed during operation.
To start the Superior Model 600, ensure the control panel is accessible and all safety precautions are in place. Turn the knob to the “Pilot” position and press until the pilot light ignites. Once lit, adjust the main burner knob to achieve the desired flame height. Use the control panel to regulate heat output and settings for optimal comfort. Always allow the unit to cool before making any adjustments. Refer to the manual for specific instructions on ignition and flame adjustment to ensure safe and efficient operation.
The control panel of the Superior Model 600 is designed for intuitive operation. It features a knob for ignition and flame adjustment, allowing you to customize the burner output. The panel includes settings for pilot, on, and off positions, ensuring precise control over the heater’s performance. Use the control panel to regulate heat output, adjust flame height, and monitor operational status. Familiarize yourself with the panel’s functions to optimize comfort and efficiency. Always refer to the manual for detailed instructions on using the control panel effectively and safely.
Ensure the Superior Model 600 operates safely by following essential precautions. Always maintain proper ventilation to prevent carbon monoxide buildup. Keep flammable materials away from the fireplace. Avoid overloading the heater and never leave it unattended while in operation. Regularly inspect the venting system for blockages or damage. If unusual odors, sounds, or flames appear, turn off the unit and consult the manual. Never attempt repairs without turning off the gas supply. Adhere to the recommended maintenance schedule to ensure optimal performance and safety. Failure to follow these guidelines may result in hazards or reduced appliance lifespan.

Regular maintenance ensures the Superior Model 600 operates efficiently and safely. Clean the fireplace and vent system, replace worn parts, and schedule annual inspections for optimal performance.

Regular cleaning of the Superior Model 600 fireplace and vent system is crucial for maintaining efficiency and safety. Use a soft brush or vacuum to remove dust and debris from the combustion chamber and vents. Clean glass surfaces with a non-abrasive cleaner to ensure clear visibility. Inspect the venting system for blockages or soot buildup, especially after extended use. Refer to the manual for detailed cleaning instructions and recommended tools. Proper maintenance prevents damage and ensures optimal performance. Always turn off the unit before cleaning and follow safety guidelines to avoid accidents.
Replacing parts and accessories for the Superior Model 600 requires careful attention to ensure compatibility and safety. Always refer to the manual for specific instructions and recommended replacement parts. Common replacements include vent restrictors, solenoid coils, and glass panels. Use genuine Superior parts to maintain performance and warranty validity. Before starting, turn off the unit and allow it to cool. For complex replacements, such as solenoid disassembly, follow the manual’s step-by-step guide or consult a professional. Regular inspections can help identify worn or damaged components early, preventing malfunctions and ensuring safe operation.
Annual inspection and servicing are crucial for maintaining the Superior Model 600’s performance and safety. Inspect the vent system for blockages or damage, clean the burner and ignition components, and ensure the control panel functions properly. Refer to the manual for a detailed checklist. Replace any worn or damaged parts with genuine Superior accessories to uphold warranty and efficiency. Consider hiring a qualified technician for complex tasks. Regular servicing prevents malfunctions and ensures optimal heating. Always follow the manual’s guidelines for servicing to maintain reliability and extend the appliance’s lifespan.

Identify and resolve issues like ignition problems, venting malfunctions, or error codes by referring to the manual’s troubleshooting guide for detailed solutions and maintenance tips.
Diagnosing ignition issues in the Superior Model 600 involves checking the gas supply, ensuring proper venting, and verifying the pilot light functionality. If the fireplace fails to ignite, first ensure the gas valve is fully open and the system is properly vented. Check for any blockages in the venting system or drafts that may interfere with ignition. Inspect the pilot light for proper flame color and stability. If issues persist, consult the manual for troubleshooting steps or contact Superior customer support for assistance. Regular maintenance can help prevent ignition-related problems. Always follow safety guidelines when diagnosing or repairing the unit.
Proper venting and draft are crucial for the Superior Model 600’s performance. Common issues include blockages in the vent system or improper vent configuration. To address these, inspect the venting system for debris or damage and ensure it is installed according to the manual’s specifications. Check for any kinks or obstructions in the vent pipes and verify that the vent cap is securely attached. If draft issues persist, ensure the vent system is properly sized and configured. In some cases, a vent restrictor may be required for vertical terminations. Always refer to the manual for specific venting requirements and solutions to maintain safe and efficient operation.

The Superior Model 600 may display error codes indicating specific issues. Refer to the manual to identify the code meaning and follow troubleshooting steps. Common malfunctions include ignition failures or inconsistent flames. Check the control panel for error codes and ensure proper electrical connections. If the issue persists, reset the system by turning it off and on. For power-related malfunctions, verify the circuit breaker and electrical supply. If unresolved, contact Superior customer support for assistance. Regular maintenance and annual inspections can help prevent malfunctions and ensure reliable operation.

The Superior Model 600 is backed by a comprehensive warranty, ensuring coverage for parts and labor. For assistance, contact Superior’s customer support team via phone or email.
The Superior Model 600 warranty provides coverage for parts and labor under specific conditions. The warranty period begins from the date of installation, not purchase. It typically includes a 5-year warranty on parts and a 1-year warranty on labor. Proper installation and maintenance, as outlined in the manual, are required to maintain warranty validity. Coverage may vary depending on regional regulations and supplier policies. For detailed terms and conditions, refer to the official warranty document provided with the product or available on the manufacturer’s website.


For assistance with the Superior Model 600, contact customer support via phone, email, or live chat through their official website. Representatives are available to address installation, operation, and maintenance inquiries. Visit the Superior support page for detailed contact information and resources. Ensure to have your model number and serial number ready for efficient service. Additionally, the website offers FAQs, troubleshooting guides, and downloadable manuals to help resolve common issues independently; Reach out to resolve concerns promptly and ensure optimal performance of your fireplace heater.
This manual provides a comprehensive guide for the Superior Model 600, ensuring safe and efficient use. Refer to it regularly for optimal performance and troubleshooting.
The Superior Model 600 manual is a comprehensive guide for installing, operating, and maintaining your direct vent gas fireplace heater. It emphasizes safety, efficiency, and proper installation techniques to ensure optimal performance. Key sections include design features, venting requirements, electrical connections, and troubleshooting common issues. Regular maintenance, such as cleaning and annual inspections, is crucial for longevity. The manual also provides detailed instructions for addressing error codes and malfunctions. By following the guidelines, users can enjoy a reliable and efficient heating experience while adhering to safety standards. Refer to the manual regularly for best practices and to resolve any operational concerns.
For the best experience with your Superior Model 600, always follow the manual’s guidelines for installation, operation, and maintenance. Schedule annual inspections to ensure safety and efficiency. Keep the venting system clean and unobstructed to maintain proper airflow. Regularly clean the fireplace and heat exchanger to prevent dust buildup. Monitor error codes and address them promptly to avoid malfunctions. Store the manual in an accessible location for quick reference. By adhering to these tips, you can enjoy consistent, reliable performance and extend the lifespan of your fireplace heater.